Compliance Results

Full SANS 10400-XA compliance report and component analysis.

Project Details

Project
Client
City
Zone
Total NFA
Active ID

Component Compliance Status

Overalls
Shading
Fenestration
Roof
Walls
Floors
Rooflights
Energy
Hot-Water
Sealing

Summary Report

Generated:

Complete Report (All Components)

Generated:

1) Project Basics

2) Orientation

Orientation (primary façade)

Choose: North, North-East, East, South-East, South, South–West, West, North-West.

# Storey Orientation Note

3) Fenestration (Table 4)

Windows / Doors

Implements SANS 10400‑XA Table 4 per storey. For each floor we compute glazing %, then apply U‑value and SHGC limits.

Total Glazed Area: 0.00
Σ U·A: 0.000
Σ SHGC·A: 0.000
Floor NFA: 0.00
Overall Glazing %: 0.0%

4) Shading (Table 3)

Shading (XA 5.2 compliance)

For overhangs/canopies, projection P must be at least H × multiplier (latitude dependent).

# Floor Window Orientation Width (m) Height (m) Method H (m) P (entered) (m) Multiplier Required P Actual P P/H Status

5) Roof

Roof assembly designer (Table 8 logic)

Product (generic) λ (W/m·K) Recommended thickness (mm)
# Material λ Thickness (mm) R (m²·K/W)

Designed added insulation R: 0.00 m²·K/W

6) Walls

SANS 10400-XA Walls — R & CR Compliance

Calculates total R-value, surface density, and CR-value.

1) Project & Compliance Context

2) Wall Assembly (inside → outside)

Layer t (mm) k (W/m·K) ρ (kg/m³) c (kJ/kg·K) R (m²·K/W) mass (kg/m²) C (kJ/m²·K)

3) Results & Compliance

Total R (incl. Rsi/Rse)
Surface density Σ(ρ·t)
— kg/m²
Areal heat capacity Σ(ρ·t·c)
— kJ/m²·K
CR-value (h)
— h
Classification:
Zone requirement:
Result:
Metal framing thermal-break (≥0.20):
Cat 1 single-leaf masonry thickness (≥140 mm):
If metal framing/sheets are present, SANS 10400-XA requires a thermal break with R ≥ 0.2 m²·K/W between metal elements. For Category 1 single-leaf masonry, nominal thickness must be ≥140 mm.

7) Floors

SANS 10400‑XA — Floors

1) Project context

Auto‑syncs with Basics.

2) Insulation R‑values

Assembly Insulation R (m²·K/W) Requirement Status
Heated slab (underfloor heating present)
or
Helper: R = t/1000 ÷ k
Suspended floor (envelope)
or
Helper: R = t/1000 ÷ k

8) Rooflights

Roof lights / skylights — Table 5 compliance

Checks the rooflight‑to‑room floor area ratio and applies Table 5 bands for U and SHGC. If the ratio is < 1.5%, “any solution” applies.

Rooflight ratio
Applicable band
Compliance
Band Max ratio (%) U ≤ SHGC ≤

9) Energy — Lighting

Lighting — Single Occupancy

Checks LPD ≤ Table 12 (SANS 10400‑XA 6.2).

Editable. Defaults to Table 12.
Auto-summed from Basics; can be overridden.
Area per sensor must be ≤ 100 m².
Internal W: 0 W
External W: 0 W
Total W: 0 W
LPD: 0.00 W/m²
Sensors A/Device:
Status:
Internal fixtures
# Type W/fixture Qty Total W Remove
External fixtures
# Type W/fixture Qty Total W Remove

10) Hot-Water

Domestic hot-water — Demand & Compliance (XA §6.1)

1) Project context

Auto-syncs with Basics.

2) Technology & supply split (XA §6.1)

Daily volume
Daily thermal (kWh)
Annual thermal (kWh)
Est. grid kWh (after EER)

4) Minimum storage (Table 10 — editable)

5) Pipe insulation (exposed)

Run Location Length (m) Thickness (mm) k (W/m·K) R-proposed R-min (Table 11) Status

6) Compliance summary

Electric supplementary ≤ 50%:
Storage (Table 10):
Pipes R (Table 11):
Technology allowed:
EER advisory (≥0.5 desirable):

11) Sealing (Airtightness)

Building sealing — XA §5.7

    Status:
    SANS 10400-XA helper — local, client-side only.