Domestic hot-water — Demand & Compliance (XA §6.1)

Calculates daily/annual hot-water energy, checks allowed technologies, ≤50% electric supplementary cap, editable Table 10 min storage for SWH/HP, and pipe insulation R checks (Table 11 – editable).

1) Project context

Auto-syncs with Basics.
Defaults are placeholders; adjust to spec.

2) Technology & supply split (XA §6.1)

XA note: electric supplementary ≤ 50% of annual average volume.
If measures are poor, EER may drop to 0.2. Improve storage/timer per XA note.

3) Demand & energy

Daily volume
Daily thermal (kWh)
Annual thermal (kWh)
Est. grid kWh (after EER)

4) Minimum storage (Table 10 — editable)

Provide the minimum tank storage for solar or heat pump systems per occupants. Defaults are placeholders — replace with the values you use for Table 10.

5) Pipe insulation (exposed) — XA §6.1.6–6.1.7

Enter proposed insulation. Requirement R-values are editable to match Table 11. Piping to be insulated includes hot supply/return, and cold water & PRV piping within 1 m of connections.

Run Location Length (m) Thickness (mm) k (W/m·K) R-proposed R-min (Table 11) Status

6) Compliance summary

Electric supplementary ≤ 50%:
Storage (Table 10):
Pipes R (Table 11):
Technology allowed (XA Note 1):
EER advisory (≥0.5 desirable):
Boost EER by larger storage/timers per XA Note 4.