Domestic hot-water — Demand & Compliance (XA §6.1)
Calculates daily/annual hot-water energy, checks allowed technologies, ≤50% electric supplementary cap, editable Table 10 min storage for SWH/HP, and pipe insulation R checks (Table 11 – editable).
1) Project context
Auto-syncs with Basics.
2) Technology & supply split (XA §6.1)
XA note: electric supplementary ≤ 50% of annual average volume.
SANS 6.1 Note 3: If measures are poor, EER may drop to 0.2.
—
3) Demand & energy
Daily volume
—
Daily thermal (kWh)
—
Annual thermal (kWh)
—
Est. grid kWh (after EER)
—
4) Minimum storage (Table 10)
—
5) Pipe insulation (exposed) — SANS 10400-XA 6.1.6 & 6.1.7
Enter proposed insulation length and thickness. Table 11 Required:
R 1.00 for ≤ 80mm dia. | R 1.50 for > 80mm dia. Piping to be insulated includes hot supply/return, and cold water / pressure relief (PRV) within 1m of connection.| Run | Location | Length (m) | Thickness (mm) | k (W/m·K) | R-proposed | R-min (Table 11) | Status |
|---|
6) Compliance summary
Electric supplementary ≤ 50%: —
Storage (Table 10): —
Pipes R (Table 11): —
Technology allowed (SANS 6.1 Note 1): —
EER advisory (SANS 6.1 Note 3): —
Boost EER by larger storage/timers per XA Note 4.